09-07-2012 03:54 PM #8
We've already hashed this out before, haven't we? You say, "Installed to spec in the trunk", and everyone here says mount it as low as possible on the frame, below the tank if at all possible. Pull the in-tank pump, as it is a flow restriction, and it may be a flow block if the pump is frozen and cannot free wheel with the flow. Then get the electric out of the trunk, mounted as low as possible and see if your problem doesn't disappear.Roger
Enjoy the little things in life, and you may look back one day and realize that they were really the BIG things.





LinkBack URL
About LinkBacks
Reply With Quote
I'm happy to see it back up, sure hope it lasts.
Back online