Welcome to Club Hot Rod!  The premier site for everything to do with Hot Rod, Customs, Low Riders, Rat Rods, and more. 

  •  » Members from all over the US and the world!
  •  » Help from all over the world for your questions
  •  » Build logs for you and all members
  •  » Blogs
  •  » Image Gallery
  •  » Many thousands of members and hundreds of thousands of posts! 

YES! I want to register an account for free right now!  p.s.: For registered members this ad will NOT show

 

Thread: Just when you think you're caught up.........
          
   
   

Results 1 to 15 of 20

Threaded View

  1. #18
    Dave Severson is offline CHR Member/Contributor Visit my Photo Gallery
    Join Date
    Jul 2003
    Location
    Madison
    Car Year, Make, Model: '67 Ranchero, '57 Chevy, '82 Camaro,
    Posts
    21,160

    Anyway, the new compressor is up and working! I set the on-off pressures at 125 on the low and 160 on the high. The compressor will put out a lot more, but who needs it? The extra tank extends the off time, and of course the run time as well. But like a car, longer run cycles and longer off time should help the longevity. I installed a small 10" fan above the pump itself and wired it to come on whenever the compressor runs to blow cool air over the pump. Probably not required, but cheap insurance. The regulators at the hose connections are set at 85 PSI. I also have the calender in the shop marked with an oil change on the pump every 60 days.....I'm going to call the manufacturer on Tuesday and see if they recommend synthetic oil in the compressor, it doesn't mention it in the papers that came with the compressor but I have noticed that many manufacturers recommend synthetic oil in their compressors.......

    I installed 90 degree drain valves in both tanks with tubing and short pieces of hose clamped to it, and a barbed T fitting with a 3/8" ID tube exiting through the outside wall...I hate having water all over the floor everytime I drain the tanks.

    I used 3/4" pipe for the air line (only 3 trips to the store to get all the right fittings, and have one hose in the little garage, and two in the big garage. I still am going to add one more shut off valve and regulator/dryer that will be dedicated to the paint guns. I'm going to use 1/2" hose and the oversized fittings on this to help with the air volume as all my guns are HVLP----my paint rep recommended this. I also put two water traps, down tubes with drain valves, on the main line.

    Next on the list is an oversized air intake tube and filter for the air intake. Hopefully the whole system will work fine and last a long time!!!!
    Last edited by Dave Severson; 05-24-2008 at 11:02 PM.
    Yesterday is history, tomorrow is a mystery, Live for Today!
    Carroll Shelby

    Learning must be difficult for those who already know it all!!!!

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
Links monetized by VigLink