ok, i checked the vacuum readings, not sure which is which but when i plugged the guage on the vacuum outlet by the choke it read 18 and the one on the opposite side read 6. So i adjusted them to read 13 and 9 and that seemed to help some. Readjusted the idle and checked the float level which front and back read correct(just under the plug.)